*Also
see our electrical
injury and burn injury videos
See our sales page for clearence items!
Product #001-0160
License and 1st set $2695, Thirty-four DVDs
All five series listed above: Grounding, Electric Supply Stations, Clearances, Strengths and Loadings, and Underground. |
|
|
Product #001-0160A
Additional sets (each) $850
|
Product #001-0166
Workbook -PDF (each) $350
|
|
(Six DVDs) General rules of NESC Sections 1-3, Grounding requireme
nts of NESC Parts 1-3, and Grounding methods of NESC Section 9. Grounding alternating current systems; Messenger wires and guys; Objectionable current flow; Fences — composition and connections of grounding conductor: Ampacity and strength; guarding and protection of grounding conductors; Common grounding of circuits, metal raceways, and equipment; Requirements and considerations when using existing grounding electrodes and made grounding electrodes; Methods of connection to electrodes; Separation of grounding conductors; Grounding methods for telephone and other communications apparatus. |


|
|
Product #001-0155A
Additional sets (each) $150
Product #001-0161
Workbook -PDF (each) $100
|
Product #001-0156
License and 1st set $495
(Six DVDs) General Rules of NESC Sections 1-3 and NESC Part 1. General requirements for enclosure of equipment in electric supply stations, including warning signs, fence height, and construction; Guarding moving parts; Protective grounding or physical isolation of noncurrent-carrying metal parts; Grounding for maintenance; Guarding or isolating live parts; Strengths and types of guards; Working space about electric equipment; Arrangement, application, fire concerns, and location requirements for circuit breakers, reclosers, switches, fuses, and switchgear assemblies; Surge arresters, grounding and location. |


|
|
Product #001-0156A
Additional sets (each) $150
Product #001-0162
Workbook -PDF (each) $100
|
| |
|
|
Product #001-0157
License and 1st set $1565
(Nineteen DVDs) General Rules of NESC Sections 1-3; Overhead General Rules of NESC Sections 20-22; NESC Clearances Rules from Part 1 (Supply Stations), Section 23 (Overhead), and Part 3 (Underground). Induced voltages, accessibility, inspection and test of lines and equipment when in service and when out of service; Grounding of circuits, supporting structures, and equipment; Tree trimming; Relations between various classes of lines—relative levels, avoidance of conflict, and joint use of structures; Building blocks used to develop clearances; Clearance relationships above roadways and non-roadway areas — a classroom exercise; Supply cable vs. covered conductors; Neutrals; Fiber optic cables; Supporting structures near hydrants and roads; Vertical clearance of wires, conductors, cables, and live parts of equipment above ground; Clearances between wires, conductors, and cables on different supporting structures; Clearances for cable risers and other vertical and lateral conductors; Clearances of wires, conductors, and cables from line structures, buildings, signs, chimneys, radio and television antennas, tanks, bridges, swimming areas, and grain bins; Horizontal and vertical clearance between line and conductors carried on the same supporting structure; Climbing space; Working space; Vertical clearance between certain communication and supply facilities. |


|
Product #001-0157A
Additional sets (each) $475
Product #001-0163
Workbook -PDF (each) $190
|
|
Product #001-0158
License and 1st set $495
(Seven DVDs) General Rules of NESC Sections 1-3 plus Strengths and Loadings Rules of NESC Sections 24-27. Grades of construction for conductors and line supports; Assumed vertical, transverse and longitudinal loading; including the traditional ice and wind loading, extreme wind loading, and the new 2007 freezing rain and wind loadings. Strength of supporting structures, foundations, settings, guys and anchors for construction; Mechanical Strength of Insulators.
|


|
|
Product #001-0158A
Additional sets (each) $150
Product #001-0164
Workbook -PDF (each) $100
|
| |
|
|
Product #001-0159
License and 1st set $415
(Five DVDs) General Rules of NESC Sections 1-3 and Underground requirements of NESC Part 3. Inspection and tests; Grounding; Underground conduit systems-location; Excavation and backfill; Ducts and joints; Manholes, handholes, and vaults; Direct buried cable — General location and routing; Separations from other underground structures; Installation including trenching and depth of burial; Random separation; Pole risers; Pad-mounted installations; Equipment—General; Design including door and barrier requirements and discussion of signing.
|


|
Product #001-0159A
Additional sets (each) $125
Product #001-0165
Workbook -PDF (each) $90
|
Product #001-0167 - $195.00
The 2007 Edition of the NESC includes general changes to improve understanability of the Code as well as nemerous changes in the required or allowed values and changes in responsiblities.
This video discusses the major changes in context showing how they work with related requirements. Where appropriate, the backgound and rationale of changes is discussed to aid users in correctly applying NESC requirements. Changes in the following rules and tables are included.
|