Distribution Secondary Design Software
Electric Distribution Powerpak

Product #019-0001— $495 - Single User License


Click Images for Larger Views

  • Calculates fault currents in service conductors
  • Calculates voltage drops and motor flicker in
        service conductors
  • Calculates voltage drop in outdoor lighting     conductors
  • Evaluates transformer, secondary and service
        conductors
  • Works for single-phase and three-phase
        voltages
  • Uses interactive graphical design palette
  • allows greater accuracy in less time


  • Multi User Pricing:

    3-User License $950
    7-User License $2095
    15-User License $4350
    25-User License $6995
    50-User License $12,495
    75-User License $19,495
    100-User License $24,995
    150-User License $35,995
    200+-User License $45,995

     

    Please call 919-782-7745 to purchase a multi-user license.

    Duke Energy and subsidiaries please contact 919-782-7745 before making an online purchase.

     

    The electrical contractor has called and needs an available fault current for your commercial project at the new mall. He needs it this afternoon for the electrical inspection.

    Doesn't that send a panic shiver up your spine? If you're like many of us, it's either been a long time since you've done this calculation, or you do it so seldom that you have to re-learn it each time.

    Even if you make cheat sheets up for yourself to remember how to do the calculations, you still have to look up transformer and cable data to make the calculations. Teaching technicians how to do the calculations is difficult. Once they learn how, you still need to check their work. Electric Distribution PowerPak is just the tool for you and your employees.

    Electric Distribution PowerPak is designed for the electric utility distribution engineer or technician to quickly calculate single-phase and three-phase secondary voltage fault currents, voltage drops and voltage flickers due to motor starting on radial systems. The program is applicable for systems with three-phase wye-wye, delta-wye, wye-delta, or delta-delta transformers and single phase transformers. Balanced loading is assumed. The program will calculate the fault current, voltage drop and voltage flicker at each meter base location and the fault current and voltage drop at the transformer secondary spades. The user can also generate a fault current quote letter for mailing to customers or local electrical inspectors.

    The simple and easy-to-use drawing palette allows the user to graphically design the secondary distribution system from transformer to meter base. Underlying the simplicity of the program are a complex graphics engine and robust calculation algorithms that provide the user with a higher level of performance productivity. Untold hours of manual calculations and potential human error are eliminated.

    In addition to the graphical design and results screens, the program includes table data for checking input values and viewing results.

     

     

    See our sales page for clearence items!

     

     

     

    upcoming seminars . seminar descriptions . registration . seminar hotels . instructors . download public seminar brochure
    download in-house seminar brochure . general information . mailing list . reward program . contact us . bookstore . links . humor and jokes

     

    © 2006-2010 Clapp Research. 877-502-8900 (toll-free). All rights reserved. Site designed by CRI Designs.